10 things to know before you buy Water softeners

Practical buying checks for water softeners, with the jargon explained.

  1. Confirm hardness before sizing Use the water supplier’s figure or a reliable test in milligrams per litre as calcium carbonate. Hardness varies by area, and equipment capacity cannot be chosen sensibly from kettle scale alone.

  2. Ion exchange is genuine softening A salt-based ion-exchange softener swaps hardness minerals, mainly calcium and magnesium, for sodium ions. Magnetic and electronic conditioners may claim to alter scale behaviour but do not remove hardness and should not be compared as equivalent systems.

  3. Capacity must match people and water use Resin volume and hardness determine how many litres can be softened before regeneration, the cleaning cycle. An undersized unit regenerates frequently and wastes salt and water; an oversized one costs more and may sit stagnant.

  4. Metered regeneration reduces waste Demand-initiated units measure actual softened water and regenerate when capacity is nearly used. Timer-only units clean on a schedule regardless of consumption, making them less suitable where occupancy varies.

  5. Keep an unsoftened drinking supply Because ion exchange adds sodium, guidance commonly retains a separate hard-water tap for drinking and cooking, particularly for infant formula or sodium-restricted diets. The installer should follow current water regulations and local advice.

  6. Check flow at simultaneous demand The softener must serve showers, taps and appliances without an unacceptable pressure drop. Compare service flow rather than peak marketing flow, and make sure the bypass valve and connecting pipework are not restrictive.

  7. Plan salt lifting and drainage Salt bags are heavy and need a dry route to the brine cabinet. Regeneration also needs a correctly trapped and air-gapped drain connection, plus a safe overflow route that remains visible.

  8. Know the annual running requirement Estimate salt and regeneration-water use from local hardness and household consumption. Include servicing, resin cleaner where prescribed and electricity for electronic controls when comparing ownership costs.

  9. Protect heating-system filling arrangements Heating manufacturers differ on whether softened water is acceptable for filling sealed systems. The installer should preserve the correct filling point and use water treatment compatible with the boiler, aluminium components and inhibitor.